null

► J.Racenstein

Water Pump Kit 12v for Spraying, Water Fed or Solar Panel cleaning

$199.95
J.Racenstein Water Pump Kit 12v for Spraying, Water Fed or Solar Panel Cleaning, compact water pump with blue hoses, brass fittings, and electrical components for efficient water spraying and cleaning applications.
J.Racenstein Water Pump Kit 12v for Spraying, Water Fed or Solar Panel Cleaning, with black water pump, blue hoses, and brass fittings.
J.Racenstein Water Pump Kit 12v for Spraying, Water Fed or Solar Panel Cleaning, illustration of the compact electric water pump with connections for hoses and power supply.
J.Racenstein Water Pump Kit 12v for Spraying, Water Fed or Solar Panel Cleaning, with diagram showing water tank, pumps, pipes, and spray connections for efficient water or chemical delivery.
J.Racenstein Water Pump Kit 12v, close-up of the compact water pump with inlet and outlet fittings for spraying, water-fed, or solar panel cleaning applications.
Water Pump Kit 12v for Spraying, Water Fed or Solar Panel cleaning
Water Pump Kit 12v for Spraying, Water Fed or Solar Panel cleaning
SKU:
150-0851
UPC:
00669893018686
MPN:
<-- KIT -->
Availability:
Current Stock:

Frequently Bought Together:

J.Racenstein Water Pump Kit 12v for Spraying, Water Fed or Solar Panel Cleaning, compact water pump with blue hoses, brass fittings, and electrical components for efficient water spraying and cleaning applications.
Inc. Tax
Ex. Tax

Description

Water-Fed Pole, Solar Brush or Chem-Wash Delivery Pump Kit with the Plumbing

Water Pump Kit 12v 90psi Pump

Pump Kit Water or Chemical Transfer Pump 110v  rated at 2.5gpm continous at 40psi

Transfer Pump for Water, SH (Sodium Hypochlorite, Bleach), Detergent Mixes, Non Flammable Fluids

Used Transfer chemicals from One Tank to another Tank

Features

  • 1/2 in. slide ports
  • Capable of running dry
  • Demand pump @ 90psi Max
  • Pressure is adjustable at the Switch on the top of the pump
  • 110v permanent magnet motor weather sealed pump
  • Totally enclosed non-venting
  • Thermally protected
  • 2ea Slide Fittings to 1/2in Tube
  • 4 Feet of Polyethylene Tubing
  • 2ea Tube to 1/2in npt Male adaptors
  • 1ea 1/2in to Garden Hose Male Fitting
  • 1ea 1/2in to Garden Hose Female Fitting
Note: Some Assembly needed for the fittings and Tubing

 

 

Typically runs at 40 to 45 psi Delivering 2.5 to 3 gallons per miute delivered to the pole/sprayer

 

             
 

Flow at

PSI

       
 

 

20 psi

40 psi

60 psi

80 psi

90 psi

 

GPM

4.5

3.8

3.2

2.5

1.9

 

In Gallons Per Minute

     
             

Capable of Running Dry for short periods

Self Priming to 10ft

Demand Style Pump @ Max 90psi

12v Permanent Magnet Motor Pump

Thermally Protected

Fittings as described are included

 

Current Requirements

 

This pump is meant to be used at medium (40 to 70psi) pressures for things like Spraying water, SH and can transfer Chemical Batches from one tank to another.

Useful for:

  • Loading RO or purified Water into a Delivery Tank on a Vehicle
  • Loading SH (Bleach) from an on property storage tank to the Tank on a Service Vehicle
  • Loading a Premixed or Mixing a Batch of Chemical mix onto a service vehicle from multipe on site Tanks.
             
 

Flow at

PSI

       
 

 

20 psi

40 psi

60 psi

80 psi

90 psi

 

GPM

4.5

3.8

3.2

2.5

1.9

 

Gallons Per Minute

     
             

Thermally protected motor, at a typical flow rate of 3 Gallons per minute will run continuously

Run a two Pump setup to get flow similar to Taps in structures. (4 gpm to 4.5 gpm at 55psi)

Thermal Protection & Continuous Duty Operation

The shaded areas in both the Performance Data and Heat Rise charts indicate pump models with operating current levels capable of continuous operation without periodic cool-down cycles. Pumps within this range will generally transfer more water over extended periods than pumps operating in the unshaded areas, which require shutdown periods for motor cooling.

Some applications, however, require maximum flow at high pressure for shorter durations. The following information explains the thermal protection considerations for these operating conditions:

1. Continuous Duty Operating Range

The Heat Rise graph identifies the highest current level that can operate continuously while remaining within the shaded area. In this case, the maximum continuous-duty current is 9.50 amps.

All pump models operating below this current level may run continuously, provided the surrounding ambient air temperature does not exceed 70°F (21°C).

2. Maximum Output Model Example

The second curve shown represents the highest flow and pressure model offered: the 55X3.

  • At 70 PSI, the 55X3 delivers:
    • 3.0 GPM
    • 18.00 amps current draw

3. Thermal Protection & Surface Temperature

The motors used in these pump models do not include built-in thermal limiting protection. Users must monitor operating conditions and understand the effects of exceeding the recommended maximum surface temperature of 150°F.

Based on the heat rise data:

  • Starting from room temperature, the 55X3 reaches the recommended shutoff temperature after approximately:
    • 8 minutes of continuous operation
    • Pumping approximately 24 gallons of water at 70 PSI

4. Cooling Requirements

Motors of this size and construction typically require:

  • Over 40 minutes to cool to approximately 120°F, where restarting is considered safe

Lower-current models heat more slowly and allow longer operating periods; however, typical cooldown time still averages approximately 30 minutes.

5. Cycling Recommendations

Certain applications may involve short bursts of water usage well below the 8-minute sustained runtime limit.

Keep in mind:

  • Startup current exceeds normal running current
  • To prevent excessive motor stress, cycling frequency should be limited to:
    • No more than 6 starts per minute

Important Notice

All performance and heat rise figures are approximate. Actual operating values will vary depending on ambient temperature and environmental conditions.

 

Slide Port Fittings allow for easy Pump removal, This could be to bring it in out of the weather or to allow for movement of the pump from on Tank Station to another Station or if the pump needs to be replaced for other reasons.

Details

CA Prop 65:
Warning: This product contains chemicals or materials known to the State of California to cause cancer, birth defects or other reproductive harm.